NORDIC COMMERCIAL
R Series Duct units (Inverter)


DESCRIPTION:

  • Easy installation;
  • Compact dimensions;
  • Drain pump;
  • Low noise fan;
  • Long lasting washable filter;
  • Effective heat dissipation of the indoor unit;
  • Self-diagnosis of malfunctions of the main blocks and modes;
  • Multilevel system protection;
  • Piping length up to 75 m. (for high power models).
R410A

MODELS:

Model CH-
IDS035PRK/
CH-
IU035RK
CH-
IDS050PRK/
CH-
IU050RK
CH-
IDS071PRK/
CH-
IU071RK
CH-
IDS085PRK/
CH-
IU085RK
CH-
IDH100PRK/
CH-
IU100RM
CH-
IDH125PRK/
CH-
IU125RM
CH-
IDH140PRK/
CH-
IU140RM
CH-
IDH160PRK/
CH-
IU160RM
Performance Cold kWh 3.5 5 7 8.5 10 12.1 13.4 16
Warm kWh 4 5.5 8 8.8 12 13.5 15.5 17
Power grid parameters ~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-2405V/
50Hz/1ph
Power consumption Cold kWh 0.95 1.55 1.55 1.55 1.55 1.55 1.55 1.55
Warm kWh 1.05 1.45 1.45 1.45 1.45 1.45 1.45 1.45
Energy efficiency Cold EER 3.68 3.23 3.23 3.23 3.23 3.23 3.23 3.23
Warm  COP 3.81 3.79 3.79 3.79 3.79 3.79 3.79 3.79
Air flow volume Indoor units m³/hour 650 950 950 950 950 950 950 950
External static pressure (nominal / maximum) Pa 25/50 25/50 25/50 25/50 25/50 25/50 25/50 25/50
Sound pressure level Indoor units dB (A) 41/38/36/34 43/42/39/36 43/42/39/36 43/42/39/36 43/42/39/36 43/42/39/36 43/42/39/36 43/42/39/36
Outdoor unit dB (A) 50 53 53 53 53 53 53 53
Refrigerant type
Refrigerant type R-32
Refrigerant charge volume Kg 0.78 1 1 1 1 1 1 1
Weight Indoor units Kg 20 26 26 26 26 26 26 26
Outdoor unit Kg 37 39 39 39 39 39 39 39
Operating temperature range Cold °C -20~48 -20~48 -20~48 -20~48 -20~48 -20~48 -20~48 -20~48
Warm °C -20~24 -20~24 -20~24 -20~24 -20~24 -20~24 -20~24 -20~24
Liquid line diameter mm/inch 6,38/1/4″ 6,38/1/4″ 6,38/1/4″ 6,38/1/4″ 6,38/1/4″ 6,38/1/4″ 6,38/1/4″ 6,38/1/4″
Gas line diameter mm/inch 9,53/3/8″ 12,70/1/2″ 12,70/1/2″ 12,70/1/2″ 12,70/1/2″ 12,70/1/2″ 12,70/1/2″ 12,70/1/2″
Maximum line height difference m 15 20 20 20 20 20 20 20
Maximum freon pipeline length m 30 35 35 35 35 35 35 35
Number of interblock cable cores (for controlling) mm² 2х0,75 2х0,75 2х0,75 2х0,75 2х0,75 2х0,75 2х0,75 2х0,75
Main power supply point
Outdoor unit
Number of cable cores (power supply internal / external) Indoor units 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²) 3 (∅ 1,0mm²)
Outdoor unit 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²) 3 (∅ 1,5mm²)
Number of freon refueling per r.m. (excess, for each r.m) jm 5 5 5 5 5 5 5 5
Number of freon refueling per r.m. (excess, for each r.m) gr/r.m. 16 16 16 16 16 16 16 16
SEER/SCOP 6,10/4,00 6,10/4,00 6,10/4,00 6,10/4,00 6,10/4,00 6,10/4,00 6,10/4,00 6,10/4,00
Energy efficiency class А++/А+ А++/А+ А++/А+ А++/А+ А++/А+ А++/А+ А++/А+ А++/А+