N4 Series Floor-ceiling units (Inverter)


DESCRIPTION:

  • Easy installation;
  • Automatic air distribution in Swing mode;
  • Compact dimensions;
  • Low noise fan;
  • Long lasting washable filter;
  • Effective heat dissipation of the indoor unit;
  • Self-diagnosis of malfunctions of the main blocks and modes;
  • Multilevel system protection;
  • Intelligent defrost;
  • Pipe length up to 50 m. (for high power models).

MODELS:

Model CH-IF09NK4/ CHIU09NK4 CH-IF12NK4/
CHIU12NK4
CH-IF18NK4/ CHIU18NK4 CH-IF24NK4/ CHIU24NK4 CH-IF36NK4/ CHIU36NM4 CH-IF42NK4/ CHIU42NM4 CH-IF48NK4/ CHIU48NM4 CH-IF60NK4/ CHIU60NM4
Performance Cold kWh 2.7 3.5 5 7 10 11.5 14 16
Warm kWh 2.9 3.8 5.6 8 12 13.5 16 17
Power supply
~220-240 V/50Hz/1ph
Rated power consumption Cold kWh 0.84 1.09 1.09 1.09 1.09 1.09 1.09 1.09
Warm kWh 0.8 1.05 1.05 1.05 1.05 1.05 1.05 1.05
Current strength Cold А 3.9 5 5 5 5 5 5 5
Warm А 3.7 4.9 4.9 4.9 4.9 4.9 4.9 4.9
Energy efficiency Cold EER 3.21 3.21 3.21 3.21 3.21 3.21 3.21 3.21
Warm COP 3.61 3.61 3.61 3.61 3.61 3.61 3.61 3.61
Air capacity m3/hour 600 700 700 700 700 700 700 700
Sound pressure level Indoor unit/ Outdoor unit dB (A) 31/29/ 26/24/52 35/33/ 30/27/52 35/33/ 30/27/52 35/33/ 30/27/52 35/33/ 30/27/52 35/33/ 30/27/52 35/33/ 30/27/52 35/33/ 30/27/52
Refrigerant type
Refrigerant type R410A
Dimensions (WxDxH) Indoor units mm 1220x700x225 1220x700x225 1220x700x225 1220x700x225 1220x700x225 1220x700x225 1220x700x225 1220x700x225
Outdoor unit mm 848х320х540 848х320х540 848х320х540 848х320х540 848х320х540 848х320х540 848х320х540 848х320х540
Weight Indoor unit/ Outdoor unit Kg 38/34 39/34 39/34 39/34 39/34 39/34 39/34 39/34
Refrigerant volume Kg 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2
Operating temperature range Cold °C -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48
Warm °C -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24
Liquid pipe line diameter mm/inch 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’ 6.35/ 1/4’’
Gas line diameter mm/inch 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’ 9.53/ 3/8’’’
Maximum line height difference m 15 15 15 15 15 15 15 15
Maximum freon pipeline length m 20 20 20 20 20 20 20 20
Number of interblock cable cores (on control)
2 * 0.75 – up to 20 m length
Main power supply point
Outdoor unit
Number of cable cores (power supply) Indoor units 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm)
Outdoor unit 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm) 3(Ø1.5 mm)
Number of freon refueling per r.m. (excess, for each r.m) m 5 5 5 5 5 5 5 5
Number of freon refueling per r.m. (excess, for each r.m) gr/r.m. 30 30 30 30 30 30 30 30
SEER/SCOP 6.1/3.8 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0 6.1/4.0