DESCRIPTION:
- Easy installation;
- Compact dimensions;
- Low noise fan;
- Long lasting washable filter;
- Drain pump;
- Automatic air distribution in Swing mode;
- High efficiency heat exchanger;
- Self-diagnosis of malfunctions of the main blocks and modes;
- Multilevel system protection;
- Intelligent defrost;
- Pipeline length up to 50 m. (for high power models);
- Possibility to select the internal air temperature sensor for control.
MODELS:
Model | CH-IC12NK4 / CH-IU12NK4 | CH-IC18NK4/ CH-IU18NK4 | CH-IC24NK4 / CH-IU24NK4 | CH-IC36NK4 / CH-IU36NM4 | CH-IC48NK4 / CH-IU48NM4 | CH-IC60NK4 / CH-IU60NM4 | ||
---|---|---|---|---|---|---|---|---|
Performance | Cold | kWh | 3.5 | 5 | 7 | 10 | 14 | 16 |
Warm | kWh | 3.8 | 5.5 | 8 | 12 | 16 | 17 | |
Power supply | ||||||||
Rated power consumption | Cold | kWh | 1.09 | 1.6 | 1.6 | 1.6 | 1.6 | 1.6 |
Warm | kWh | 1.05 | 1.58 | 1.58 | 1.58 | 1.58 | 1.58 | |
Current strength | Cold | А | 5 | 7.2 | 7.2 | 7.2 | 7.2 | 7.2 |
Warm | А | 4.9 | 7.6 | 7.6 | 7.6 | 7.6 | 7.6 | |
Energy efficiency | Cold | EER | 3.21 | 3.12 | 3.12 | 3.12 | 3.12 | 3.12 |
Warm | COP | 3.61 | 3.48 | 3.48 | 3.48 | 3.48 | 3.48 | |
Air capacity | m3/hour | 700 | 760 | 760 | 760 | 760 | 760 | |
Sound pressure level | Indoor unit / Outdoor unit | dB (A) | 46/45/41/36/52 | 47/46/44/37/56 | 47/46/44/37/56 | 47/46/44/37/56 | 47/46/44/37/56 | 47/46/44/37/56 |
Refrigerant type | ||||||||
Refrigerant volume | Kg | 1.2 | 1.4 | 1.4 | 1.4 | 1.4 | 1.4 | |
Dimensions (WxDxH) | Indoor units | mm | 596х596х240 | 596х596х240 | 596х596х240 | 596х596х240 | 596х596х240 | 596х596х240 |
Indoor units | mm | 670х670х50 | 670х670х50 | 670х670х50 | 670х670х50 | 670х670х50 | 670х670х50 | |
Paneel | ||||||||
Outdoor unit | mm | 848х320х540 | 955х396х700 | 955х396х700 | 955х396х700 | 955х396х700 | 955х396х700 | |
Weight | Indoor unit / Outdoor unit | Kg | 20/34 | 20/47 | 20/47 | 20/47 | 20/47 | 20/47 |
Operating temperature range | Cold | °C | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 |
Warm | °C | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | |
Liquid pipe line diameter | mm/inch | 6.35/ 1/4’’ | 6.35/ 1/4’’ | 6.35/ 1/4’’ | 6.35/ 1/4’’ | 6.35/ 1/4’’ | 6.35/ 1/4’’ | |
Gas line diameter | mm/inch | 9.53/ 3/8’’ | 12.70/ 1/2’’ | 12.70/ 1/2’’ | 12.70/ 1/2’’ | 12.70/ 1/2’’ | 12.70/ 1/2’’ | |
Maximum line height difference | m | 15 | 15 | 15 | 15 | 15 | 15 | |
Maximum freon pipeline length | m | 20 | 20 | 20 | 20 | 20 | 20 | |
Number of interblock cable cores (on control) | ||||||||
Main power supply point | ||||||||
Number of cable cores (power supply) | Indoor units | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | |
Outdoor unit | / 3(Ø1.5 mm) | / 3(Ø2.5 mm) | / 3(Ø2.5 mm) | / 3(Ø2.5 mm) | / 3(Ø2.5 mm) | / 3(Ø2.5 mm) | ||
Number of freon refueling per r.m. (excess, for each r.m) | r.m. | 5 | 5 | 5 | 5 | 5 | 5 | |
Number of freon refueling per r.m. (excess, for each r.m) | gr/r.m. | 30 | 30 | 30 | 30 | 30 | 30 | |
SEER/SCOP | 5.6/4.0 | 5.6/3.8 | 5.6/3.8 | 5.6/3.8 | 5.6/3.8 | 5.6/3.8 |