DESCRIPTION:
- Easy installation;
- Compact dimensions;
- Low noise fan;
- Long lasting washable filter;
- Drain pump;
- Self-diagnosis of malfunctions of the main blocks and modes;
- Multilevel system protection;
- Piping length up to 75 m (for high power models);
- Selectable indoor air temperature sensor for control.
MODELS:
Model | CH-IC035NK/CH-IU035NK | CH-IC050NK/CH-IU050NK | CH-IC071NK/CH-IU071NK | CH-IC100NK/CH-IU100NM | CH-IC125NK/CH-IU125NM | CH-IC140NK/CH-IU140NM | CH-IC160NK/CH-IU160NM | ||
---|---|---|---|---|---|---|---|---|---|
Performance | Cold | kWh | 3.5 | 5 | 7 | 10.1 | 12.02 | 14 | 15.4 |
Warm | kWh | 4 | 5.6 | 8 | 11 | 14 | 15 | 17 | |
Power grid parameters | ~ 220-240V/ 50Hz/1ph |
~220-2405V/ 50Hz/1ph |
~220-240V/ 50Hz/1ph |
~220-2405V/ 50Hz/1ph |
~380-415V/ 50Hz/1ph |
~380-415V/50Hz/1ph | ~380-415V/50Hz/3Ph | ||
Power consumption | Cold | kWh | 1.03 | 1.56 | 2.18 | 3.4018 | 4.5 | 5 | 5.2 |
Warm | kWh | 1.1 | 1.6 | 2.2 | 3 | 4.2 | 4.4 | 4.8 | |
Power current | Cold | А | 4.45 | 6.78 | – | 16.3 | 7.6 | 8.6 | 9 |
Warm | А | 4.8 | 7 | – | 14.4 | 7.2 | 7.6 | 8.4 | |
Energy efficiency | Cold | EER | 3.4 | 3.21 | 3.21 | 2.97 | 2.67 | 2.8 | 2.96 |
Warm | COP | 3.64 | 3.5 | 3.64 | 3.67 | 3.33 | 3.41 | 3.54 | |
Air capacity | m³/hour | – | – | – | – | – | – | ||
Sound pressure level | Indoor unit | dB (A) | – | – | – | – | – | – | |
Sound pressure level | Outdoor unit | dB (A) | 51 | 55 | – | 55 | 58 | 59 | 60 |
Freon type | |||||||||
Dimensions (WxDxH) | Indoor unit | mm | 570/265/570 | 570/265/570 | 570/265/570 | 840/240/840 | 840/240/840 | 840/290/840 | 580/265/580 |
Indoor unit panel | mm | 620/-/620 | 620/-/620 | 620/-/620 | 950/-/950 | 950/-/950 | 950/-/950 | 620/-/620 | |
Outdoor unit | mm | 818/596/302 | 818/596/302 | 892/340/698 | 488/855/1083 | 940/820/460 | 940/820/460 | 940/820/460 | |
Weight | Indoor unit / Outdoor unit | Kg | /37 | /37 | /53 | /61 | /90 | /96 | /100 |
Freon quantity | Kg | 1 | 1.25 | 2 | 2.45 | 3.4 | 3.7 | 3.8 | |
Temperature range | Cold | °C | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 | -15 … +48 | -20 … +48 |
Warm | °C | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | -20 … +24 | |
Liquid pipe line diameter | mm/inch | 6.38/1/4” | 6.38/1/4” | 9.53/3/8” | 9.53/3/8” | 9.53/3/8” | 9.53/3/8” | 9.53/3/8” | |
Liquid pipe line diameter | mm/inch | 9.53/3/8” | 12.7/1/2” | 15.88/5/8” | 15.88/5/8” | 15.88/5/8” | 15.88/5/8” | 15.88/5/8” | |
Maximum line height difference | m | 15 | 20 | 25 | 25 | 30 | 30 | 30 | |
Maximum freon pipeline length | m | 30 | 35 | 50 | 50 | 65 | 75 | 75 | |
Mounting distance of the bolts of the outdoor unit | mm | 550 | 550 | 560 | 610 | 610 | 610 | 610 | |
Number of interblock cable cores (for controlling) | |||||||||
Main power supply point | |||||||||
Number of cable cores (for controlling indoor / outdoor units) | Indoor unit | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | 3(Ø1.0 mm) | |
Outdoor unit | 3(Ø2.5 mm) | 3(Ø2.5 mm) | 3(Ø2.5 mm) | 3(Ø4.0 mm) | 5(Ø1.5 mm) | 5(Ø1.5 mm) | 5(Ø1.5 mm) | ||
Factory refrigerant charge volume (for the number of running meters) | m | 5 | 5 | 5 | 5 | 5 | 7.5 | 7.5 | |
Freon filling quantity per r.m | gr/r.m. | 22 | 22 | 22 | 30 | 35 | 50 | 50 |