NORDIC COMMERCIAL
IN Series Cassette units (Inverter)


DESCRIPTION:

  • Easy installation;
  • Compact dimensions;
  • Low noise fan;
  • Long lasting washable filter;
  • Drain pump;
  • Self-diagnosis of malfunctions of the main blocks and modes;
  • Multilevel system protection;
  • Piping length up to 75 m (for high power models);
  • Selectable indoor air temperature sensor for control.
R410A

MODELS:

Model CH-IC035NK/CH-IU035NK CH-IC050NK/CH-IU050NK CH-IC071NK/CH-IU071NK CH-IC100NK/CH-IU100NM CH-IC125NK/CH-IU125NM CH-IC140NK/CH-IU140NM CH-IC160NK/CH-IU160NM
Performance Cold kWh 3.5 5 7 10.1 12.02 14 15.4
Warm kWh 4 5.6 8 11 14 15 17
Power grid parameters ~ 220-240V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~220-240V/
50Hz/1ph
~220-2405V/
50Hz/1ph
~380-415V/
50Hz/1ph
~380-415V/50Hz/1ph ~380-415V/50Hz/3Ph
Power consumption Cold kWh 1.03 1.56 2.18 3.4018 4.5 5 5.2
Warm kWh 1.1 1.6 2.2 3 4.2 4.4 4.8
Power current Cold А 4.45 6.78 16.3 7.6 8.6 9
Warm А 4.8 7 14.4 7.2 7.6 8.4
Energy efficiency Cold EER 3.4 3.21 3.21 2.97 2.67 2.8 2.96
Warm COP 3.64 3.5 3.64 3.67 3.33 3.41 3.54
Air capacity m³/hour
Sound pressure level Indoor unit dB (A)
Sound pressure level Outdoor unit dB (A) 51 55 55 58 59 60
Freon type
Refrigerant type R410A
Dimensions (WxDxH) Indoor unit mm 570/265/570 570/265/570 570/265/570 840/240/840 840/240/840 840/290/840 580/265/580
Indoor unit panel mm 620/-/620 620/-/620 620/-/620 950/-/950 950/-/950 950/-/950 620/-/620
Outdoor unit mm 818/596/302 818/596/302 892/340/698 488/855/1083 940/820/460 940/820/460 940/820/460
Weight Indoor unit / Outdoor unit Kg  /37  /37  /53  /61  /90  /96  /100
Freon quantity Kg 1 1.25 2 2.45 3.4 3.7 3.8
Temperature range Cold °C -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -15 … +48 -20 … +48
Warm °C -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24 -20 … +24
Liquid pipe line diameter mm/inch 6.38/1/4” 6.38/1/4” 9.53/3/8” 9.53/3/8” 9.53/3/8” 9.53/3/8” 9.53/3/8”
Liquid pipe line diameter mm/inch 9.53/3/8” 12.7/1/2” 15.88/5/8” 15.88/5/8” 15.88/5/8” 15.88/5/8” 15.88/5/8”
Maximum line height difference m 15 20 25 25 30 30 30
Maximum freon pipeline length m 30 35 50 50 65 75 75
Mounting distance of the bolts of the outdoor unit mm 550 550 560 610 610 610 610
Number of interblock cable cores (for controlling)
2 * 0.75 – with a length of 20 m
2 * 1.0 – with a length of more than 20 m
Main power supply point
Outdoor unit
Number of cable cores (for controlling indoor / outdoor units) Indoor unit 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm) 3(Ø1.0 mm)
Outdoor unit 3(Ø2.5 mm) 3(Ø2.5 mm) 3(Ø2.5 mm) 3(Ø4.0 mm) 5(Ø1.5 mm) 5(Ø1.5 mm) 5(Ø1.5 mm)
Factory refrigerant charge volume (for the number of running meters) m 5 5 5 5 5 7.5 7.5
Freon filling quantity per r.m gr/r.m. 22 22 22 30 35 50 50