DESCRIPTION:
- “CH 7-SKY Technology” – a complex filtration system based on seven broad-spectrum filters;
- “CH SMART-ION Filter” – a new generation of total air purification technology;
- Temperature range for effective operation from -15 ° C to + 24 ° C for heat, from -15 ° C to + 48 ° C for cold;
- Wi-Fi module for air conditioning control via Smartphone / Tablet (OS: Android, iOS);
- Protection of your home from freezing: function “+ 8 ° C”. The air conditioner will maintain a temperature of 8 ° C, preventing freezing of the room and using a minimum of electricity;
- Self-cleaning indoor unit;
- Premium energy-saving GENERATION V package (increased quality control of assembly and materials);
- “I-Action” technology – smooth and stable compressor operation at ultra-low frequencies (1Hz);
- Wide-angle blinds that cover the entire volume of the room.
MODELS:
MODEL | CH-S09FTXF2-NG | CH-S12FTXF2-NG | CH-S18FTXF2-NG | CH-S24FTXF2-NG | ||
Capacity | Cooling | kWh | 2.50 (0.50-3.35) | 3.20 (0.60-3.60) | 4.60 (0.65-5.20) | 6.2 (2.00-8.20) |
Heating | kWh | 2.80 (0.50-3.30) | 3.40 (0.60-3.80) | 5.20 (0.70-5.40) | 6.5 (2.00-8.50) | |
Power supply | ~220-240 /50 Hz/1 Ph | |||||
Power input | Cooling | kWh | 0.78 (0.16-1.40) | 0.99 (0.16-1.40) | 1.35 (0.16-1.70) | 1.83 (0.16-2.50) |
Heating | kWh | 0.78 (0.20-1.50) | 0.94 (0.20-1.50) | 1.34 (0.20-1.60) | 1.91 (0.20-2.60) | |
Energy efficiency | Cooling (SEER*)/ |
kW/kW | 6.1 (А++) | 6.1 (А++) | 6.4 (А++) | 6.8 (А++) |
Heating (SCOP**) |
kW/kW | 5,1(A+++)/ 4.0 (А+) |
5,1(A+++)/ 4.0 (А+) |
5,1(A+++)/ 4.0 (А+) |
5,1(A+++)/ 4.0 (А+) |
|
Air Flow Volume | m3/h | 330/430/490/550 | 300/430/500/550 | 600/700/800/850 | 400/600/800/900 | |
Sound Pressure Level | Indoor | dB(A) | 28/35/37/40 | 28/35/37/42 | 31/38/42/44 | 30/37/45/48 |
Outdoor | 52 | 52 | 55 | 57 | ||
Refrigerant | R32 | |||||
Net Weight | Indoor Outdoor |
kg | 8,5 29 |
8,5 31 |
13,5 26,5 |
13 36,5 |
Compressor Type | Rotary | |||||
Dehumidifying Volume | l/h | 0.8 | 1,4 | 1,8 | 1,8 | |
Cooling Operation Ambient Temperature Range | °C | -15/+43 | -15/+43 | -15/+43 | -15/+43 | |
Heating Operation Ambient Temperature Range | °C | -15/+24 | -15/+24 | -15/+24 | -15/+24 | |
Refrigerant Charge | kg | 0,6 | 0,65 | 0,75 | 1,23 | |
Outer Diameter Liquid Pipe | mm/toll | 6.38/1/4″ | 6.38/1/4″ | 6.38/1/4″ | 6.38/1/4″ | |
Outer Diameter Gas Pipe | mm/toll | 9.53/3/8″ | 9.53/3/8″ | 9.53/3/8″ | 12.7/1/2″ | |
Max Distance Height | м | 10 | 10 | 10 | 10 | |
Max Distance Length | м | 15 | 20 | 25 | 25 | |
Dimension Indoor Unit (WXHXD) | mm | 773 x 250 x 185 | 773 x 250 x 185 | 970 x 300 x 225 | 970 x 300 x 225 | |
Dimension Outdoor Unit (WXHXD) | mm | 782 x 540 x 320 | 848 x 596 x 320 | 732 x 555 x 330 | 873 x 555 x 376 |
* SEER – Seasonal Energy Efficient Ratingin the cooling mode.
** SCOP – seasonal system capacity ratio in the heating mode.